Homepage | Set Home | Add to Favorites
Member

Yueqing Langir Electric Co., Ltd.


Products
  • No Category
Search
 

Friends links
  • No link

Cm1309 Micro Switch
Click image to view full size image
Product: Views:291Cm1309 Micro Switch 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-12-20 10:13
  Inquiry
Details

Features
Virous of actuators, action position is adjustable (such as CM1701)
High switch on and off capacity(15A)
High accuracy
Wide range of operation speed
Each type of CM series has solder terminal, screw terminal and tab terminal are selective
Add A for solder terminal, add C for tab terminal, blank for screw terminal

Ratings

Rated Voltage
(V)
Noninductive Load
(A)
Inductive Load
(A)
Inrush Current
Resistance Load Lamp Load Inductive Load Motor Load
NC NO NC NO NC NO NC NO NC NO
125VAC
250VAC
500VAC
15
15
3
3
2.5
1.5
1.5
1.25
0.75
15
15
2.5
5
3
1.5
2.5
1.5
0.75
30 max. 15 max.
8VDC
14VDC
30VDC
125VDC
250VDC
15
15
6(2)
0.4
0.2
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
15
10
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03

Characteristics

Operation speed 0.01mm-1m/sec
Operating frequency Mechanical: 240 operations/min.
Electrical: 20 operations/min.
Contact resistance 15mΩ max. (initial value)
Insulation resistance 100mΩ min. (at 500VDC)
Dielectric strength 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between currentcarrying and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
Vibration frequency 10-55HZ,1.5mm double amplitude
Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S)
Malfunction: 300m/Sec2 (about 30G'S)
Ambient temperature General purpose type: -25ºC to +80ºC, Sealed type: -15ºC to +80ºC
Humidity General purpose type: 85% RH max., Sealed type: 95% RH max.
Life Mechanical: 20,000,000 operations min.
Electrical: 500,000 operations min.
Weight About 22g to 58g
Degree of protection IP65

Operating characteristics

Models CM1300 CM1301 CM1303 CM1305 CM1306 CM1307 CM1308 CM1309 CM1701
OF Max. 350g 300g 300g 350g 350g 350g 350g 350g 70g
RF Min. 114g 50g 50g 114g 114g 114g 114g 114g 14g
PT Max. 0.4mm 4mm 4mm 0.4mm 0.4mm 0.4mm 0.4mm 0.4mm 10mm
OT Min. 0.13mm 1.6mm 1.6mm 1.6mm 1.6mm 5.5mm 3.58mm 3.58mm 5.6mm
MD Max. 0.05mm 1.3mm 1.3mm 0.05mm 0.05mm 0.05mm 0.05mm 0.05mm 1.27mm
FP Max.   20.6mm 31.8mm           28.2mm
OP(mm) 15.9 ±0.4 mm 17.4 ±0.8 mm 28.6 ±0.8 mm 28.2 ±0.5 mm 21.5 ±0.5 mm 21.50. ±8 mm 33.4±1.2 mm 33.4±1.2 mm 19 ±0.8 mm
 
Models CM1702 CM1703 CM1704 CM1705 CM1743
OF Max. 160g 100g 160g 10g 160g
RF Min. 28g 22g 42g 3g 42g
PT Max. 5mm 7.1mm 2.7mm 20mm 2.7mm
OT Min. 2mm 4mm 2.4mm 5.6mm 2.4mm
MD Max. 1mm 1.02mm 0.5mm 3mm 0.5mm
FP Max. 24.8mm 36.5mm 32.5mm   43.6mm
OP(mm) 19 ±0.4 mm 30.2 ±0.8 mm 30.2 ±0.4 mm 19±0.4 mm 43.1 ±0.8 mm

Definitions of operating characteristics:

  • OF: operating force
    Force needed to add to the executer unit to actuate switch contact
    RF: releasing force
    Force needed to add to the execter unit to make the switch contact back to normal position
    TF: total force
    Force needed to make executer unit move from free position to limitation position
    FP: free position
    Primary position of executer unit without external force adding to executer unit
    OP: operating position
    The position of executer unit in case of the contact rapidly moving to the contact position for action
    RP: releasing position
    The position of executer unit in case of the contact rapidly backing to normal position to action contact position 
    TTP: total tavel position
    The position of executer unit in case of executer unit reaching the limitation position
    PT: pretravel
    The distance or angle that the executer unit passes since free position to action position
    OT: overtravel
    The distance or angle that the executer unit surpasses action position
    MD: movement differential
    The distance or angle from action position to reversion position
    TT: total tavel
    The distance or angle represents the movement till action and the total movement after all actions.
Inquiry